Hualing Pulse Vacuum Double Door Sterilizer YXQ.MG-208II-D

Hualing Pulse Vacuum Sterilizer YXQ.MG-208II-D Double Door Built-in steam generator One loanding cart, two trolleys
Manufacturer: Hua Ling Sterilizer
SKU: YXQ.MG-208II-D
*

The steel material for the large machine chamber and jacket

Call for pricing

Model: YXQ.MG Automatic Double Doors
Application Range:
The sterilizer is used to sterilize wrapped, instruments, vessels, culture medium, and small amount of liquid in unsealed bottles.
Quality System:
The sterilizer is designed and manufactured according to ISO 9001-2000 and ISO 13485-2003 quality manage system.
Safety System:
The sterilizer has multiple safety structures, including overpressure protection, low water-level protection, door interlock system, overload and short circuit protection, which ensure safety operation.
Insulation: The sterilizer’s chamber is covered with rock wool to avoid heat emission.
Technical Specification:
Chamber
1. The chamber is made of stainless steel (customer option: SUS 304 or SUS 316L). It is designed and manufactured according to ASME standard, which ensures safety of pressure vessels.
2. The chamber surface is finely polished, glabrous, corrosion-proof and easy to clean.
3. The equipment has over-pressure protection device---safety valve, which is safe and reliable.
Safety valve
Door Structure
1. The sterilizer has automatic door structure. Operator can open and close door with easy touch on the panel.
2. The doors of sterilizer are sealed by silicone rubber inflatable with compressed-air.
3. It has double-door safety interlock system. When the door is not closed, steam can not enter the chamber. When chamber steam pressure is not safety pressure, the doors cannot open.
Pipeline System
1. The pipeline system is composed of control valve, pipelines and filter.
2. The control valve is pneumatic valve, which has advantages of strong heat resistance performance, reliable operation and low fault rate, which ensures overall performance of sterilizer.
3. The pipelines are stainless steel, clamps connected; it is easy for installation and maintenance.
Control System
1. The control system is mainly composed of PLC (customer option: MITSUBISHI or SIMENSE). The whole system operates reliably and controls precisely, which ensure overall performance and sterilizing effect.
PLC
2. The control system has HMI, it has functions including multiple sterilizing processes for users to choose, setting the sterilizing parameters, displaying the parameters and the cycle phases, printing the sterilizing reports, users can also choose manual operation for special requirement.
OPERATION PANEL
3. The printer is used for recording and printing data of time, temperature and the pressure in the operation process.
PRINTER
Vacuum System:
1. Vacuum system is used for disposing of cool air, keeping uniform temperature in the chamber.
VACUUM PUMP
2. The vacuum system of sterilizer is mainly composed of liquid ring vacuum pump, vacuum valve and pipelines. Among these, the vacuum pump is the key part. The vacuum system has good advantages of operating stably, low voice, high vacuum and fast air suction, which ensures sterilizing effect and whole performance.
Sterilizing Programs:
Two kinds of operation mode: automatic and manual;
Automatic operation mode:
Instruments Sterilizing Program:
It is used for sterilizing the metal apparatus, vessels and tools. The sterilizing program is composed of pulsation vacuum, rising temperature, sterilizing (keeping the same temperature for a certain time) and cooling. The users can set the sterilizing parameters according to goods’ characteristics and manufacturing requirements. The setting range of the sterilizing parameters is: Sterilizing Pressure: 0.07-0.22Mpa; Sterilizing
Temperature115-134℃, Sterilizing Time: 1-99minutes.
Wrapped Sterilizing Program:
It is used for sterilizing the wrapped and dressing bag. The sterilizing program is composed of pulsation vacuum, rising temperature and sterilizing (keeping the same temperature for a certain time) and drying. The users can set the sterilizing program according to the goods’ characteristics and manufacturing requirements. The setting range of the sterilizing parameters is: Sterilizing Pressure: 0.07-0.22MPa, sterilizing temperature, 115-134℃, sterilizing time 1-99minutes, drying time 1-99minutes.
Liquid Sterilizing Program:
It is used for sterilizing the less amount of liquid in the unsealed bottles and culture medium. The sterilizing program is composed of warming-up, rising temperature and sterilizing (keeping the same temperature for a certain time) and cooling. The users can set the sterilizing parameters according to the goods’ characteristics and the manufacturing requirements. The setting range of the sterilizing parameters is: Sterilizing Pressure: 0.07-0.22Mpa; Sterilizing Temperature: 115-134℃;Sterilizing Time: 1-999 minutes.
BD-test: It is used to test air removal and steam penetration.
User can operate manually if have special requirement;

Products specifications
Sterilizer Type Automatic Sterilizer
Vacuum Pump Yes
Sterilizer Power Voltage 208V Three Phases
Dry Mode Yes
Loading Methods Loading Cart
Sterilizer Program Full Automatic One Button
Sterilizer High Temperature 275F (134C)
Printer Option
Color Stainless
Type of Heating Element External Heating Element
Sterilizer Speed Standard
Type of Door Automatic Sliding Door
Laboratory Customer Yes
Industry Customer Yes
Government Customer Yes
ASME Certificate Yes
GMP Certificate Yes
Sterilizer Door Size 26" x 30"
Sterilizer Chamber Depth 65 inches
Sterilizer Dimension 73" x 52" x 27" (685mm x 1855mm x 1310mm)
Sterilizer Chamber Volume 211 Gal/800 L
Sterilzier Power Current 30A
Warranty Parts and Labor 1 year